Copper Gate Valve

High-quality copper gate valves designed for reliable flow control in residential, commercial, and industrial plumbing systems.

View Technical Specs
DIN Resilient Seated NRS Gate Valve

Product Overview

AILAN Tech's Copper Gate Valves are precision-engineered for superior performance in various plumbing applications. Constructed from high-quality copper alloys, these valves provide excellent corrosion resistance and durability, making them ideal for use with water, oil, and other non-corrosive fluids.

Our copper gate valves feature a full-port design that minimizes pressure drop and maximizes flow capacity. The rising stem design allows for easy visual indication of the valve's position, while the robust construction ensures reliable operation even in demanding environments.

Available in a range of sizes from DN15 to DN100, with both threaded and solder connections, our copper gate valves meet the highest industry standards and are suitable for use in residential, commercial, and light industrial applications.

Key Features & Benefits

Corrosion Resistance

High-quality copper construction provides excellent resistance to corrosion, ensuring long service life in various environments.

Full-Port Design

Full-bore opening minimizes pressure drop and maximizes flow capacity, ensuring efficient system operation.

Rising Stem

Visual indication of valve position for easy operation and maintenance, with stem protection from damage and corrosion.

Easy Operation

Smooth turning handwheel requires minimal effort to open or close the valve, even after long periods of inactivity.

Leak-Free Performance

Precision-machined components and high-quality seals ensure tight shut-off and reliable performance over time.

Easy Installation

Available with threaded or solder connections for quick and easy installation in new or existing plumbing systems.

Technical Specifications

Basic Parameters

Parameter Specification Range
Nominal Diameter (DN) DN15 ~ DN100
Pressure Rating PN10, PN16, PN25
Operating Temperature -10°C ~ 120°C
Applicable Media Water, Oil, Gas, Non-corrosive fluids
End Connection Threaded (NPT, BSP), Solder

Material Specifications

Component Material Options Standards/Features
Body & Bonnet Brass (C37700), Bronze (C83600), Copper Alloy High strength, corrosion resistance
Gate Brass, Bronze, Stainless Steel Smooth operation, wear resistance
Stem Brass, Stainless Steel Corrosion resistance, smooth operation
Seat PTFE, NBR, EPDM Excellent sealing performance
Handwheel Cast Iron, Plastic, Stainless Steel Ergonomic design, durable

Standards & Compliance

  • Design Standards: EN 1074-1, AWWA C509, MSS SP-80
  • Testing Standards: EN 12266-1, API 598
  • Certifications: CE, WRAS, ACS, NSF/ANSI 61

Working Principle

Copper gate valves operate on a simple yet effective principle to control the flow of fluids in plumbing systems:

  1. Flow Control: The valve consists of a gate (or wedge) that moves up and down perpendicular to the flow direction. When the gate is fully raised, the valve is open, allowing maximum flow. When the gate is fully lowered, the valve is closed, stopping all flow.
  2. Operation: Turning the handwheel rotates the stem, which moves the gate up or down. The rising stem design shows the valve's position visually - when the stem is extended, the valve is open; when retracted, it's closed.
  3. Sealing: When closed, the gate presses against the valve seats, creating a tight seal that prevents leakage. The seats are typically made of soft materials like PTFE or rubber for excellent sealing performance.
  4. Pressure Management: The full-port design minimizes pressure drop when the valve is open, allowing for efficient system operation. The robust copper construction ensures the valve can withstand the pressure and temperature requirements of various applications.

Application Areas

Residential Plumbing

Ideal for use in homes, apartments, and condominiums for water supply systems, including main shut-off valves, branch lines, and fixture connections.

Commercial Buildings

Suitable for office buildings, hotels, shopping centers, and other commercial structures for water supply, HVAC systems, and fire protection systems.

Institutional Facilities

Used in hospitals, schools, universities, and government buildings for reliable water flow control in various systems and applications.

Light Industrial

Suitable for light industrial applications such as food processing, pharmaceuticals, and electronics manufacturing where clean water and reliable flow control are essential.

Hospitality Industry

Ideal for hotels, resorts, and restaurants for water supply systems, including guest rooms, kitchens, laundry facilities, and swimming pools.

Plumbing Renovations

Perfect for renovation projects where existing plumbing systems need to be upgraded or modified with reliable, high-quality components.

Installation & Maintenance

Installation Guidelines

  • Ensure the valve is compatible with the system's pressure and temperature requirements.
  • Install the valve in the correct orientation, with the flow direction matching the arrow on the valve body.
  • For threaded valves, use Teflon tape or pipe dope on the male threads to ensure a leak-free connection.
  • For solder valves, follow proper soldering techniques, ensuring the valve is open during soldering to prevent damage to internal components.
  • Tighten all connections securely but do not over-tighten, which could damage the valve or pipes.
  • Test the valve after installation to ensure proper operation and check for leaks.

Maintenance Recommendations

  • Operate the valve regularly (at least once per year) to prevent seizing and ensure smooth operation.
  • Inspect the valve periodically for signs of leakage, corrosion, or damage.
  • Clean the valve exterior regularly to remove dirt and debris that could affect operation.
  • Lubricate the stem threads if the valve becomes difficult to operate.
  • Replace the valve if it shows signs of significant wear, corrosion, or damage that cannot be repaired.
  • Keep records of maintenance activities for future reference.

Frequently Asked Questions (FAQ)

Q: What is the maximum pressure rating for copper gate valves?

A: Our copper gate valves are available with pressure ratings up to PN25 (25 bar), making them suitable for most residential, commercial, and light industrial applications.

Q: Can copper gate valves be used with hot water systems?

A: Yes, our copper gate valves are designed to handle temperatures up to 120°C, making them suitable for both hot and cold water systems.

Q: What is the difference between threaded and solder connections?

A: Threaded connections use screw threads for installation, while solder connections require heating and melting solder to create a permanent bond. Threaded valves are easier to install and remove, while solder valves provide a more permanent, leak-proof connection.

Q: How long do copper gate valves typically last?

A: With proper installation and maintenance, copper gate valves can last 20-50 years or more, depending on the operating conditions and water quality.

Q: Are copper gate valves suitable for potable water systems?

A: Yes, our copper gate valves are certified to meet NSF/ANSI 61 standards for use in potable water systems, ensuring they are safe for drinking water applications.

Need Custom Solutions?

Our engineering team can customize Copper Gate Valves to meet your specific pressure, temperature, and media requirements. Contact us today for a personalized quote.

Contact Our Technical Team